Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Wallac 1450 MicroBeta TriLux Liquid Scintillation Counter & Lumi, Max. Sample Vial Diameter 13 mm, Wallac (CAT#: STEM-AIAEPO-0212-LGZ)

Highlights

Parallel count mode function.
Equipped with a barcode reader.
Can be used with 1, 2, 3, 6 or 12 detectors.

Cat Number: STEM-AIAEPO-0212-LGZ

Application: For liquid scintillation or luminescence detection of samples in microplates, tubes or filters.

Add to Cart



Description

The Wallac MicroBeta® TriLux is today's leading multi-detector liquid scintillation counter and luminometer.
Three MicroBeta® models meet specific needs. Two variants with sample capacity up to 16 or 32 plates, with manual loading. The third model has a fully automated loading procedure by using a robotic loading system. The last model was fitted with an external loading platform.
Wallac 1450 MicroBeta® TriLux is suitable for assays using 3H, 14C, 32P, 33P, 35S, 51Cr, 125I and luminescent labels. The instrument also has excellent performance when used with ScintiPlate, FlashPlate and other scintillation proximity assays. In addition to microtiter plates, 1450 TriLux counting filters and tubes.

Specification

Condition: certified pre-owned
Dimensions (H x W x D / Weight): 560 mm x 650 mm x 770 mm / 128 kg
Electrical requirements: 120 V +- 10% at 50/60 Hz
Environmental requirements: Temperature range from +15’C to +35’C, maximum humidity 85%
Max. sample vial diameter: 13 mm
Max. sample vial cap diameter: 14 mm
Max. sample vial height: 90 mm, including height
Sample vial shape: No restrictions
Sample racks: Plastic racks, 10 samples/rack
Sample changer: Bi-directional with storage capacity of 55 racks or 100 racks
Sample ID: 2 barcodes for each rack
Detector system: 50 mm x 32 mm thallium activated
Dimensions (H x W x D / Weight): 560 mm x 650 mm x 770 mm / 128 kg
Electrical requirements: 120 V +- 10% at 50/60 Hz
Environmental requirements: Temperature range from +15’C to +35’C, maximum humidity 85%
Max. sample vial diameter: 13 mm
Max. sample vial cap diameter: 14 mm
Max. sample vial height: 90 mm, including height
Sample vial shape: No restrictions
Sample racks: Plastic racks, 10 samples/rack
Sample changer: Bi-directional with storage capacity of 55 racks or 100 racks
Sample ID: 2 barcodes for each rack
Detector system: 50 mm x 32 mm thallium activated

Features

Parallel count mode function.
Equipped with a barcode reader.
Can be used with 1, 2, 3, 6 or 12 detectors.
Store up to 100 normalized or counted protocols.
Freely selectable data export options.

Related Products

Beckman Coulter LS6500 Liquid Scintillation Counter, Ambient Temperature Range 15 – 35 °C, Beckman Coulter (CAT#-STEM-AIAEPO-0201-LGZ)
Beckman LS 5000 Scintillation Counter, Versatile System Design, Beckman Coulter (CAT#-STEM-AIAEPO-0202-LGZ)
Packard Topcount NXT HTS Model C384V00, External Plate Stacker With 15,000 Sample Capacity, Packard Cobra (CAT#-STEM-AIAEPO-0203-LGZ)
Packard TopCount NXT Scintillation Counter, Hologram ODBC, Packard Cobra (CAT#-STEM-AIAEPO-0204-LGZ)
Packard Tri-Carb Liquid Scintillation Counter, Bi-Directional Conveyor Track, Packard Cobra (CAT#-STEM-AIAEPO-0205-LGZ)
Perkin Elmer 1450 Microbeta Classic, Password Protection, Perkin Elmer (CAT#-STEM-AIAEPO-0206-LGZ)
Advertisement