Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

X-Porator H1 Electroporator (CAT#: STEM-CC-0009-ZJF)

Highlights

Upgraded to H1plus after one year of enhancements, including 21 electronic and structural improvements, 17 software upgrades, and 41 additional refinements, resulting in superior quality and performance.
Compatible with flow electroporators for optimized parameter setting and validation.
Patented HiDEN High Density Electrode Needle technology creates a stable, uniform electrical field, ensuring high transfection efficiency.

Cat Number: STEM-CC-0009-ZJF

Application: For Electroporation

Model: EBXP-H1

Add to Cart



Description

The X-Porator H1, also known as a gene import device, is the result of four years of research and development by Etta Biotech. This device incorporates several patented technologies to achieve precise control of pulse voltage, waveform, duration, interval, and repetition. The HiDEN high-density matrix needle electrode creates a stable and even electric field, effectively facilitating the transfer of exogenous substances into target cells.

Specification

Transfection Volume per Well: 60-3,000 μl
Voltage Waveform: Square Wave
Pulse Voltage Range: 1-400 V
Square Wave Duration: 10-100,000 μs
Pulse Interval: 15-10,000 ms
Number of Pulses: 1-100
Electrode Type: HiDEN Electrode for 96-, 24-, or 12-well plates / Electrode Cuvette
Wireless Transmission Distance: 15 m
Operating System Platform: Android
Input Voltage: 210-240 VAC
Dimensions: W220 × D408 × H180 mm
Weight: 8.2 kg

Features

Upgraded to H1plus after one year of enhancements, including 21 electronic and structural improvements, 17 software upgrades, and 41 additional refinements, resulting in superior quality and performance.
Compatible with flow electroporators for optimized parameter setting and validation.
Patented HiDEN High Density Electrode Needle technology creates a stable, uniform electrical field, ensuring high transfection efficiency.
HiDEN technology reduces required voltage and minimizes OH- formation during electroporation, enhancing cell protection and viability.
Accommodates various transfection volumes, supporting up to 3000μl in a single transfection—3 to 29 times higher than other models on the market.
Compatible with standard 96-well, 24-well, and 12-well plates using cuvettes and HiDEN electrodes, eliminating the need for special cuvettes or vectors for easy and cost-effective use.
Electrode Docking Station supports use with PBMC common cuvettes.
Wireless control system enables operation inside a clean bench, reducing contamination risk, enhancing convenience, and shortening operation time to improve cell viability.
Professional after-sales service with a dedicated team offering immediate online or on-site technical support.
Low-cost consumables at approximately
{PARAVALUE}
per treatment, with reusable electrodes.

Related Products

STEM-CC-0010-ZJF
STEM-CC-0011-ZJF
Advertisement