1200 Series G1315B Diode Array Detector (DAD), Agilent Technologies (CAT#: STEM-CPO-0328-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-CPO-0328-ZJF

Application: For chromatography

Model: 1200 Series G1315B

Add to Cart



Description

The manufacturer of the 1200 Series G1315B Diode Array Detector (DAD), Agilent Technologies is Agilent Technologies.
Refurbished Agilent 1200 Series G1315B DAD Diode Array Detector with standard flow cell.
The Agilent Technologies 1200 Series G1315B DAD Diode Array Detector has a series of 1024 individual photodiodes and control circuits contained in a ceramic carrier. This system has a wavelength range from 190 – 950 nm the sampling interval is < 1 nm.

Specification

Condition: Refurbished, Certified Pre-owned
Wavelength range: 190-950 nm
Light source: Deuterium and tungsten lamps
Detection type: 1024 – element photodiode array
Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
Drift: 2° x 10-3 AU / hr at 254 nm
Linear absorbance range: > 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Wavelength bunching: 1 – 400 nm
Diode width: < 1 nm
Flow cells:
Standard: 13µl volume 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
Micro: 2µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum
High Pressure: 1.7µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure max.
80 nano: 0.08µl volume, 100 mm cell path length and 50 bar (725 psi) pressure max.
500 nano: 0.5µl volume, 10 mm cell path length and 50 bar (725 psi) pressure max.
Analog outputs: Recorder / integrator:
10 mV or 1 V, output range 
0.001 – 2 AU, two outputs
Control and data evaluation: Agilent Chemstation for LC
Slit width: 1, 2, 4, 8, 16 nm
Communication types: CAN, GBIP, RS-232C, APG, Remote: ready, start, stop and shut down
Wavelength range: 190-950 nm
Light source: Deuterium and tungsten lamps
Detection type: 1024 – element photodiode array
Short term noise (ASTM) single & mult-wavelength: ± 1° x 10-5 AU at 254 and 750 nm
Drift: 2° x 10-3 AU / hr at 254 nm
Linear absorbance range: > 2 AU (upper limit)
Optional: Agilent G1315A-60022 flow cell (13ul, 10mm path length, 120bar).

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty