Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector, Agilent Technologies (CAT#: STEM-C-0051-LGZ)

Highlights

1. Agilent 1100 HIGH Performance Liquid Chromatography G1365B Multi-wavelength Detector is a dedicated multi-wavelength detector that provides superior sensitivity for single and multi-wavelength detection.
2. The MWD uses deuterium and tungsten lamps and has a wavelength range of 190 to 950 nm, extending the detection range with the lowest detection limit.
3. The G1365B's diode array is capable of simultaneous acquisition of up to eight compound specific wavelengths, which improves sensitivity and selectivity.

Cat Number: STEM-C-0051-LGZ

Application: For HPLC system.

Model: 1100 Series G1365B

Add to Cart



Description

The manufacturer of Agilent 1100 Series - G1365B HPLC Multi-Wavelength Detector is Agilent Technologies. Model is 1100 Series G1365B. You can use Agilent 1100 Series G1365B Multi-wavelength Detector to a spectral acquisition to your HPLC analysis. And the quality of separation was verified by peak purity, multiple signals, and spectral libraries – interactively or automatically in the same run as your analytical quantification.

Specification

Condition: used
Detection type: 1024-element photodiode array
Light source: Deuterium and tungsten lamps
Wavelength range: 190 – 950 nm
Short term noise (ASTM) Single and Multi-Wavelength: ± 1 × 10-5AU at 254 and 750 nm
Drift: 2 × 10-3AU/hr at 254 nm
Linear absorbance Range: 2 AU (upper limit)
Wavelength accuracy: ± 1 nm
Wavelength bunching: 1 – 400 nm
Slit width: 1, 2, 4 , 8, 16 nm
Diode width: < 1 nm
Flow cells
Standard: 13 µL volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum
Semi-Micro: 5 µL volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum
High pressure: 1.7 µL volume, 6 mm cellpath length and 400 bar (5880 psi) pressure maximum
500 nano: 0.5 µL volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data Evaluation: Agilent ChemStation for LC
Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintenance: Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter

Features

1. Agilent 1100 HIGH Performance Liquid Chromatography G1365B Multi-wavelength Detector is a dedicated multi-wavelength detector that provides superior sensitivity for single and multi-wavelength detection.
2. The MWD uses deuterium and tungsten lamps and has a wavelength range of 190 to 950 nm, extending the detection range with the lowest detection limit.
3. The G1365B's diode array is capable of simultaneous acquisition of up to eight compound specific wavelengths, which improves sensitivity and selectivity.
4. Programmable slit ranges from 1 to 16 nm for rapid optimization of sensitivity, linearity, and spectral resolution.

Related Products

Waters Acquity TUV Detector UPLC TUV Detector, Waters Corporation(CAT#-STEM-C-0136-LGZ)
Pharmacia Optical Unit UV-1 FPLC UV Detector, Pharmacia Fine Chemicals(CAT#-STEM-C-0249-LGZ)
Precision Detectors PD2123 HPLC Absorbance Detector, Thermo Fisher Scientific(CAT#-STEM-C-0253-LGZ)
Dionex RI-101 HPLC Refractive Index Detector, Dionex Corporation(CAT#-STEM-C-0266-LGZ)
Dionex Ultimate 3000 VWD-3100 HPLC Variable Wavelength Detector, Thermo Fisher Scientific(CAT#-STEM-C-0302-LGZ)
Dynamax UV-DII HPLC Absorbance Detector, Rainin(CAT#-STEM-C-0306-LGZ)