Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Agilent 1200 Series - G2260A HPLC Preparative Autosampler, Agilent Technologies (CAT#: STEM-C-0079-LGZ)

Highlights

1. The flow rate is as high as 100 mL/minute, at 400 bar.
2. The injection volume range ranges from 10-900 μL (optional as many as 5 mL).
3. Flexible and convenient sample processing with different types of sample containers (2-ml and 6-ml bottle).

Cat Number: STEM-C-0079-LGZ

Application: For HPLC system.

Model: 1200 Series - G2260A

Add to Cart



Description

The manufacturer of Agilent 1200 Series - G2260A HPLC Preparative Autosampler is Agilent Technologies. Model is 1200 Series - G2260A. The Agilent 1200 Series preparative autosampler is designed to perform preparative LC. It allows the volume of small bottle samples from µL to mL range. By adding the Agilent 1200 series thermostat for ALS/FC/spots, you can upgrade from the non -constant temperature version to the constant temperature version.

Specification

Condition: used
Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5800psi)
GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range:
900 µL in 0.1 µL increments (recommended 1 µL increments)
Up to 1800 µL with multiple draw (hardware modification required)
Up to 5000 µL with multiple draw (hardware modification required)
Replicate injections: – 99 from one vial
Precision:
Typically < 0.5% RSD of peak areas from 5 – 2000 µL
Typically < 1% RSD of peak areas from 2000 – 5000 µL
Typically < 3% RSD of peak areas from 1 – 5 µL
Minimum sample volume:
µl from 5 µl sample in 100 µL microvial
1 µl from 10 µl sample in 300 µL microvial
Sample viscosity range: 0.2 – 50 cp
Sample capacity:
100 × 2-mL vials in 1 tray
15 × 6-mL vials in ½ tray (Agilent vials only)
Injection cycle time: Typically 50 s, depending on draw speed and injection volume

Features

1. The flow rate is as high as 100 mL/minute, at 400 bar.
2. The injection volume range ranges from 10-900 μL (optional as many as 5 mL).
3. Flexible and convenient sample processing with different types of sample containers (2-ml and 6-ml bottle).
4. Peltier temperature is controlled at 4-40 °C, which can be used for up to 100 2 -ML bottle, which contains heat instability samples (may be upgraded from the non -constant temperature version to the constant temperature version).

Related Products

Agilent 1100 Series - G1329A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0043-LGZ)
Agilent 1100 Series - G1367A HPLC Well Plate Autosampler, Agilent Technologies(CAT#-STEM-C-0052-LGZ)
Agilent 1100 Series - G1377A HPLC Well Plate Autosampler, Agilent Technologies(CAT#-STEM-C-0054-LGZ)
Agilent 1100 Series - G1389A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0056-LGZ)
Agilent 1100 Series - G2260A HPLC Preparative Autosampler, Agilent Technologies(CAT#-STEM-C-0058-LGZ)
Agilent 1200 Series - G1329A HPLC Autosampler, Agilent Technologies(CAT#-STEM-C-0071-LGZ)
Advertisement