Agilent 6100 Quadrupole LC/MS Systems, Weight 50 kg, HP Agilent (CAT#: STEM-CPO-0034-LGZ)

Highlights

Orthogonal Flow Nebulizer with Pneumatic Nebulizer - Improves sensitivity and reduces maintenance requirements over a wide range of LC conditions.
Large Capacity Solvent Drying System - Reduces chemical noise and allows analysis of heat sensitive compounds with user control of gas flow and gas temperature.
Media Platinized Capillary - Improves sensitivity, allows independent optimization of spray chamber and ion optics, and allows dynamic optimization of in-source fragmentation.

Cat Number: STEM-CPO-0034-LGZ

Application: For LC/MS analysis.

Add to Cart



Description

Best data quality in a space-saving desktop package. Agilent 6100 Series systems can be upgraded to meet your needs and budget, allowing you to:

• Quickly screen compounds and confirm molecular weights.
• Purification of target compounds in complex mixtures.
• Quantification of target compounds.
• Actively identify impurities.

Unparalleled speed of analysis increases productivity
•Faster acquisition speed lets you take full advantage of UHPLC separations.
• Ultra-fast ion polarity switching, even with narrow LC peaks, to obtain maximum information from a single implant.
• Faster injection-to-injection cycle times let you run more samples per hour.

Advanced Analytical Capabilities Increase Confidence
• Even at scan speeds up to 10,000 u/s, you get excellent spectral quality and precise isotope ratios for identity and confirmation.
• Variable energy, in-source, collision-induced dissociation (CID) provides valuable structural information.
• Multi-signal capability lets you analyze more compounds per run.

Simple and intuitive operation saves time and improves results
• Intuitive Agilent ChemStation software lets you set up and control the LC and MS from one screen; integration with MassHunter software adds analytical capabilities.
• Powerful auto-tuning feature eliminates the need for manual recalibration.
• Comprehensive automation capabilities allow for walk-in sample submission and unattended operation.

Specification

Condition: certified pre-owned
Mass Range: 6130 Quad: m/z 2 – 3000
Mass Accuracy: ± 0.13 u within the calibrated mass range in scan mode
Mass Axis Stability: The mass drift does not exceed the larger absolute value of ± 0.1 Da or ± 100 ppm of measured mass over a 12 hour period at constant temperature ± 3 degrees centrigrade.
Scan Speed: 6130 Quad: 2500 u/s standard mode, 5250 u/s fast scan mode
SIM Sensitivity:
• ESI at 400 µ/min or APCI at 1000 µ/min
• Selected ion monitoring of m/z 609.3
• Positive ionization
6130 and 6140 Quad: 1 pg reserpine, 100:1 RMS (20:1 peak-to-peak)
Scan Sensitivity*:
• ESI at 400 µ/min or APCI at 1000 µ/min
• Scan range m/z 100 – 650
• Scan speed 2500 u/s
• Extracted ion at m/z 609.3
• Positive ionization
6130 and 6140 Quad: 50 pg reserpine, 100:1 RMS (20:1 peak-topeak)
Flow Rate:
ESI: Up to 1.0 ml/min water without a flow splitter
APCI: Up to 1.5 ml/min water without a flow splitter
Multisignal acquisition (6120, 6130 and 6140 Quad only): Ability to cycle through four acquisition modes on a scan-by-scan basis within a single run. Up to four analysis modes can be viewed in the software window and can be linked together to facilitate processing and analysis. Modes of operation: positive/negative polarity switching, variable fragmentor voltage selection, and concurrent SIM/scan.
Operating Conditions: Temperature range: 15 °C to 35 °C (59 °F to 95 °F) Relative humidity: less than 95 % (non-condensing)
Dimensions** Height: 65 cm (26 in) Width: 39 cm (15 in) Depth: 75 cm (29 in W:
Height: 65 cm (26 in)
Width: 39 cm (15 in)
Depth: 75 cm (29 in
Weight: 50 kg (110 pounds)
**Approximate maximum cabinet dimensions with G1947A APCI source attached but without external mechanical pump. Height and width slightly less with G1948A ESI source.

Features

Orthogonal Flow Nebulizer with Pneumatic Nebulizer - Improves sensitivity and reduces maintenance requirements over a wide range of LC conditions.
Large Capacity Solvent Drying System - Reduces chemical noise and allows analysis of heat sensitive compounds with user control of gas flow and gas temperature.
Media Platinized Capillary - Improves sensitivity, allows independent optimization of spray chamber and ion optics, and allows dynamic optimization of in-source fragmentation.
Air-Cooled Turbomolecular Pump - Provides fast start-up and a small footprint, and eliminates the need for cooling water. Single-split turbo pumps increase performance and reliability.
Score Collection Capability - Score collection can be monitored and triggered based on quality, analog signal input, or time. For mass-based determinations up to 16 m/z values can be monitored. Requires optional I/O accessory module.

Related Products

GE AKTA Prime Plus Liquid Chromatography System, Flow Rate 0.1 ml/min-50 ml/min, GE AKTA (CAT#-STEM-CPO-0011-LGZ)
GE AKTA Pure Preparative Chromatography System, UV Wavelength 280 nm, GE AKTA (CAT#-STEM-CPO-0012-LGZ)
GE AKTA Start Chromatography System, Flow Rate 0.5 – 5 ml/min, GE AKTA (CAT#-STEM-CPO-0013-LGZ)
GE Pharmacia AKTA Purifier 10, GE AKTA (CAT#-STEM-CPO-0014-LGZ)
GE Pharmacia AKTA Purifier 10 UPC, GE AKTA (CAT#-STEM-CPO-0015-LGZ)
GE Pharmacia AKTA Purifier 100, GE AKTA (CAT#-STEM-CPO-0016-LGZ)
Advertisement