Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

BD Biosciences FacsCanto II - 3 Laser Flow Cytometer, BD Biosciences (CAT#: STEM-CA-1150-LGZ)

Highlights

1. Incorporates a patented optical design that enhances signal retention for 6 fluorescence and 2 scattering parameters, digital electronic processing up to 10,000 times/sec, and a novel sample injection tube that supports less than 0.1% carryover.
2. Best Fluorescence Sensitivity.
3. Minimal sample contamination for cleaner data.

Cat Number: STEM-CA-1150-LGZ

Application: For cell assay research.

Model: FacsCanto II 3

Add to Cart



Description

The manufacturer of BD Biosciences FacsCanto II - 3 Laser Flow Cytometer is BD Biosciences. Model is FacsCanto II 3. The BD FACSCanto System Breakthrough Flow Cytometry is a six-color benchtop analyzer. It incorporates many of the technological advancements first developed in the BD LSR II Scalable Analyzer and the BD FACSAria Cell Sorter. It supports a wide range of research applications and is especially suited for high speed, high sensitivity, minimal sample-to-sample carryover for rare event analysis. System includes: Computer w/ FacsDiva Software, Fluids Cart, 2 laser, Blue(488) and Red (633), Laser, 6 PMTs unit and side scatter, All Necessary Cables, Manuals.

Specification

Condition: used
Lasers
Air-cooled:
488-nm solid state, 20-mW laser output
633-nm HeNe, 17-mW laser output
Laser Configuration: Spatially separated beams with 9 x 65-μm elliptical spots
Optical Alignment Procedure: Fixed, no operator alignment required
Flow Cell: 180 x 430-μm rectangular quartz flow cell
Collection Optics: Optical-gel coupled 1.2 NA lens
FSC Resolution: 0 μm
SSC Resolution: 5 μm
Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT
FSC Detector: Photodiode with 488/10 BP
SSC Detector: PMT with 488/10 BP
Fluorescence Detectors: 6 PMTs in 4-2 standard configuration
Blue Laser Dyes
FITC, PE, PerCP or PerCP-Cy™5.5,
PE-Cy7 (525, 575, 678 or 695, 785 nm)
Red Laser Dyes: APC, APC-Cy7 (660, 785 nm)
Detector Bands
Blue Laser: 530/30; 585/42; >670; 780/60 nm
Red Laser: 660/20; 780/60 nm
Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF

Features

1. Incorporates a patented optical design that enhances signal retention for 6 fluorescence and 2 scattering parameters, digital electronic processing up to 10,000 times/sec, and a novel sample injection tube that supports less than 0.1% carryover.
2. Best Fluorescence Sensitivity.
3. Minimal sample contamination for cleaner data.
4. Fast processing speed, saving precious time for science.
5. Overcome the barriers of rare event analysis and low detection range functional studies.

Related Products

Luminex Guava Muse Cell Analyzer, Luminex(CAT#-STEM-CA-0546-LGZ)
Millipore Muse Cell Analyzer, Millipore(CAT#-STEM-CA-0549-LGZ)
NanoString Technologies nCounter Sprint Profiler Cell Analyzer, NanoString(CAT#-STEM-CA-0550-LGZ)
Becton Dickinson FACSMicroCount Microbe Counter, Becton Dickinson(CAT#-STEM-GA-0561-LGZ)
Guava EasyCyte Flow Cytometer, Guava(CAT#-STEM-CA-0751-LGZ)
Millipore Guava easyCyte HT Flow Cytometer, Guava(CAT#-STEM-CA-0756-LGZ)
Advertisement