Highlights

1. In manual operation, a single run parameter needs to be entered before each run.
2. During the programming operation, it is possible to repeat the operation by selecting one of the ten programs previously entered into the program memory.
3. Each program can contain up to five steps.

Cat Number: STEM-LC-1595-LGZ

Application: To generate high centrifugal force for a variety of high-speed applications.

Model: Optima Max 130000

Add to Cart



Description

The manufacturer of Beckman Coulter Optima Max 130000 Benchtop Centrifuge is Beckman Coulter. Model is Optima Max 130000. The instrument is designed with variable frequency induction drive, thermoelectric temperature control system, self-blowing vacuum system, rotor overspeed identification system, and can contain up to ten five-step program memory, and the acceleration and deceleration rates are also selectable.

Specification

Condition: used
Only values with tolerances or limits are guaranteed data. Values without tolerances are informative data, without guarantee.

Speed

Set speed:
Optima MAX: 5 000 to 130 000 rpm in 1 000-rpm increments
Optima MAX-E: 5 000 to 100 000 rpm in 1 000-rpm increments
Speed control: actual rotor speed, ±50 rpm of set speed
Speed display: actual rotor speed in 100-rpm increments above 5 000 rpm and 10-rpm increments at speeds below 5 000 rpm
Time

Set time: to 99 hours 59 minutes
Time display
Manual operation: indicates run time remaining
Programmed operation: time remaining in step
Temperature
Set temperature: 0 to 40 °C in 0.1 ° increments
Temperature control (after equilibration): ±2 °C of set temperature
Temperature display: actual rotor temperature in 0.1° increments
Ambient temperature range: 15 to 35 °C
Humidity restrictions: <95% (noncondensing)
Vacuum: below 10 microns (1.34 Pa)
Acceleration: 10 acceleration profiles—9 slow rates from 0 to 5 000 rpm followed by full acceleration to set speed; or maximum acceleration
Deceleration: 11 deceleration profiles—10 slow rates n from 5 000 to 0 rpm, including coasting to a stop without brake; or full dynamic braking from set speed
Dimensions
Width: 73.7 cm (29 in.)
Depth: 58.4 cm (23 in.)
Height: 58.4 cm (23 in.)
Weight: 99 kg (217 lb)
Ventilation clearances (sides and rear): 7.6 cm (3.0 in.)
Finishes
Control panel: coated polycarbonate
Top surface: urethane paint
Other surfaces: general purpose paint
Electrical requirements
100-V instrument: 90–110 VAC, 12 A, 50/60 Hz
120-V instrument: 100–130 VAC, 12 A, 50/60 Hz
220/240-V instrument: 198–254 VAC, 6 A, 50 Hz
Maximum heat dissipation into room under
steady-state conditions: 1750 Btu/hr (0.5 kW)
Noise level 0.91 m (3 ft) in front of centrifuge: <60 dBa
Installation category: II
Pollution degree: 2

Features

1. In manual operation, a single run parameter needs to be entered before each run.
2. During the programming operation, it is possible to repeat the operation by selecting one of the ten programs previously entered into the program memory.
3. Each program can contain up to five steps.
4. Provide user information and/or audible signals to alert situations that may require attention.
5. An optional feature of the Optima MAX or MAX-e is the RS 232C interface accessory, which can be connected to a personal computer. Information about this feature will be provided upon request.

Related Products

Eppendorf 5430R Benchtop Refrigerated Centrifuge, Eppendorf (CAT#-STEM-LC-1470-LGZ)
Eppendorf 5702 Benchtop Centrifuge, Eppendorf (CAT#-STEM-LC-1471-LGZ)
Eppendorf 5702R Benchtop Refrigerated Centrifuge, Eppendorf (CAT#-STEM-LC-1472-LGZ)
Eppendorf 5702RH Benchtop Refrigerated/ Heated Centrifuge, Eppendorf (CAT#-STEM-LC-1473-LGZ)
Eppendorf 5804 Benchtop Refrigerated Centrifuge, Eppendorf (CAT#-STEM-LC-1474-LGZ)
Eppendorf 5804R Benchtop Refrigerated Centrifuge, Eppendorf (CAT#-STEM-LC-1475-LGZ)
Advertisement