Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Extensible Test Chamber, Overall Dimensions 1503×910×1820 mm, Internal Size 1220×585×1123 mm, 2100 W, Shanghai Boxun Medical Biological Instrument Corp. (CAT#: STEM-GLE-0416-LGH)

Highlights

Touch type operation, so that the experimental operation is more simple;
Fuzzy PID control, programmed multi-stage parameter setting: 30 stage 99 cycle design;
The operating system is based on the WINDOWS CE platform with large memory space and high frequency CPU;

Cat Number: STEM-GLE-0416-LGH

Application: Is mainly used in pharmaceutical, medical, biotechnology, food industry and other industries, electronic industry and all include the related fields of life science, is a scientific method to create a long time needed for evaluation of drug failure and stable temperature, humidity and light environment is suitable for the pharmaceutical companies accelerated test of medicines and drugs, long-term experiment, high temperature test, It is the selection scheme of drug stability test for pharmaceutical enterprises.

Model: BXS-800

Add to Cart



Description

Extensible Test Chamber, BXS-800, Shanghai Boxun Medical Biological Instrument Corp.
1. LCD touch screen, large 4.3 "TFT16 true color display;
2. Touch type operation, so that the experimental operation is more simple;
3. Fuzzy PID control, programmed multi-stage parameter setting: 30 stage 99 cycle design;
4. The operating system is based on the WINDOWS CE platform with large memory space and high frequency CPU;
5. Adopt energy-saving and environmental protection compressor, high performance fan;
6. Data storage function, can save 250,000 data records;
7. Real-time view instrument temperature record data (the latest time 1600);
8. Frequency conversion refrigeration system, rapid temperature recovery after opening the door;
9. Screensaver password lock function to prevent random operation;
10. Perfect protection function: overtemperature limit alarm and shutdown protection, door opening alarm, sensor fault alarm;
11. USB directly export memory data and instrument event records (including startup, shutdown, menu parameter Settings, fault alarm, etc., with the exact time);
12. Glass interior observation door design;
13. C.H. circulating heat system to improve the utilization of residual heat and reduce heating time;
14. The device is configured with USB ports, RS232 ports and RS485 ports.
15. Standard mechanical lock to prevent random opening;
16. Standard embedded printer;

Specification

Temperature control range: 0-70℃
Resolution: 0.1℃
Fluctuation (25℃) : ±0.5℃
Uniformity (25℃) : ±1.5℃
Input power: 2100W
Timing range: 30 segments 99 cycles/each segment 1-9999 hours
Tank size (L × W × H) (mm) : 1220×585×1123
Dimensions (L × W × H) (mm) : 1503×910×1820
Load carrier (standard/Max.) : 8 /16

Features

Touch type operation, so that the experimental operation is more simple;
Fuzzy PID control, programmed multi-stage parameter setting: 30 stage 99 cycle design;
The operating system is based on the WINDOWS CE platform with large memory space and high frequency CPU;
Advertisement