Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

Life Tech Attune NxT Flow Cytometer, Violet: 405 nM, Life Tech Attune (CAT#: STEM-CCPO-0022-YJL)

Highlights

Modular design—Multiple configurations available—this one has them all !
Simplified sample prep—No wash, no lyse options, non-clogging fluidics
Enables unique applications—Complex protocols on a broad range of cell types and samples

Cat Number: STEM-CCPO-0022-YJL

Application: It is useful for no wash, no lyse immunophenotyping protocols using whole blood and for samples that are inherently low in concentration, including cerebrospinal fluid and stem cell preparations.

Model: NxT

Add to Cart



Description

Life Tech Attune NxT Flow Cytometer, Violet: 405 nM, model NxT, is manufactured by Life Tech Attune. The Attune NxT can be designed to accommodate most common fluorophores and fluorescent proteins used in flow cytometry to match most panels you are currently running. Multiple fluorescent proteins can be detected with an (optional) 561 nm laser. The Attune NxT flow cytometer, designed to use acoustic-assisted hydrodynamic focusing, and consequently achieves sample-throughput rates of of 12.5 µL/min–1 mL/min or 12.5–1,000 µL/min—up to 10 times faster than traditional hydrodynamic focusing systems and data acquisition speeds of 35,000 events/sec. Acoustic focusing allows significantly higher sample rates, which simplifies sample preparation, reduces protocol times, and minimizes cell loss.
Billed as a personal flow cytometer, the Attune NxT AFC2 matches the most sophisticated multi laser multi color instruments on the market today and meets the demands of the most complex experiments.

Specification

Condition: Certified Pre-Owned
Lasers: Violet: 405 nM (50 mW); Blue: 488 nM (50 mW); Yellow: 561 nM (50 mW); Red: 637 nM (100 mW)
Filters: VL1: 440/50; VL2: 512/25; VL3: 603/48; VL4: 710/50; RL1: 670/14; RL2: 720/30; RL3: 780/60; YL1: 585/16; YL2: 620/15; YL3: 695/40; YL4: 780/60; BL1: 530/30; BL2: 590/40; BL3: 695/40
Scatter: Forward scatter: Photodiode detector with 488/10; Side scatter: PMT with 488/10
Control and Analysis: Dell Desktop with Intel CORE i7 with Windows 7; Attune NxT Software version 2.2; Dell Flat Panel LCD monitor
Automated maintenance: startup (less than 15 min), shutdown, rinse, wash, debubble, deep clean, monthly decontamination
Gates: standard and customizable gates
Graphics resolution: publication-quality images (customizable)
Probe Design: Intelligent probe design minimizes clogging and carryover (less than 1%) – helps prevent damage to the instrument
Sample Mixing: Mixes sample by aspiration to maintain sample homogeneity and cell viability
Laser: Simmer mode: automatic shutoff prolongs laser usage lifetime by 10xPre-aligned and welded fiber to laser interfacePre-aligned fiber to beam-shaping optics (BSO) interface (alignment-free)All lasers spatially separatedFocus lens per laser: power where you want itFlat-top laser specified at the flow cell Benefits of flat-top lasers
~50% reduction in scattered light
No problems with lateral shift in alignment

Features

Modular design—Multiple configurations available—this one has them all !
Simplified sample prep—No wash, no lyse options, non-clogging fluidics
Enables unique applications—Complex protocols on a broad range of cell types and samples
Customized 4-laser, 14-color system
Data at up to 35,000 events/second.
Detect particles with diameters from 0.5 μm to 50 μm.

Related Products

BD Biosciences FACSCount Flow Cytometer, BD (CAT#: STEM-CCPO-0016-YJL)
BD FACS Canto II Flow Cytometry system, 10-210 uL/min, BD (CAT#: STEM-CCPO-0017-YJL)
Beckman Coulter Epics MCL 4 Color Flow Cytometry Analyzer, 300nm – 800nm, Beckman Coulter (CAT#: STEM-CCPO-0019-YJL)
Beckman Coulter Epics XL MCL 5 Color Flow Cytometry Analyzer, 100 tests/hour, Beckman Coulter (CAT#: STEM-CCPO-0020-YJL)
Beckman Coulter FC 500 MCL Flow Cytometry Analyzer, Patient Sample Capacity: 32, Beckman Coulter (CAT#: STEM-CCPO-0021-YJL)
Advertisement