Metabolic profiling of Escherichia coli by ion mobility-mass spectrometry with MALDI ion source (CAT#: STEM-ST-0099-LJX)

Introduction

Comprehensive metabolome analysis using mass spectrometry (MS) often results in a complex mass spectrum and difficult data analysis resulting from the signals of numerous small molecules in the metabolome. In addition, MS alone has difficulty measuring isobars and chiral, conformational and structural isomers. When a matrix-assisted laser desorption ionization (MALDI) source is added, the difficulty and complexity are further increased. Signal interference between analyte signals and matrix ion signals produced by MALDI in the low mass region (<1500 Da) cause detection and/or identification of metabolites difficult by MS alone. However, ion mobility spectrometry (IMS) coupled with MS (IM-MS) provides a rapid analytical tool for measuring subtle structural differences in chemicals. IMS separates gas-phase ions based on their size-to-charge ratio.




Principle

Ion mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.

Applications

For studying the gas phase ion structure
For detecting the chemical warfare agents and explosives
For the analysis of proteins, peptides, drug-like molecules and nano particles
For monitoring isomeric reaction intermediates and probe their kinetics
For proteomics and pharmaceutical analysis

Procedure

1. Add sample
2. The ions in the sample are separated in the ion mobility spectrometer
3. The separated ions are introduced into the mass analyzer for detection
4. Store the detection results

Materials

• Sample Type:
Escherichia coli

Notes

1. Ion mobility spectrometry is also a very fast technique, making it suitable for high-throughput applications. The entire analysis can be completed in just a few minutes.
2. The method is extremely sensitive and able to detect trace amounts of contaminants that other spectrometry methods would miss.
3. The effective separation of analytes achieved with this method makes it widely applicable in the analysis of complex samples such as in proteomics and metabolomics.