Unlock Exclusive Discounts & Flash Sales! Click Here to Join the Deals on Every Wednesday!

AD20 Absorbance Detector, Dionex (CAT#: STEM-CPO-0378-ZJF)

Highlights

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned

Cat Number: STEM-CPO-0378-ZJF

Application: For chromatography

Model: AD20

Add to Cart



Description

The manufacturer of the AD20 Absorbance Detector, Dionex is Dionex.
Refurbished Dionex AD20 Absorbance Detector (AD 20). (p/n AD20-1) The Dionex AD20 Absorbance Detector is a dual-beam, variable wavelength photometer. Full spectral capability is provided by two light sources: a deuterium lamp for ultraviolet detection and a tungsten lamp for visible wavelength operation. The Dionex AD20 features programmable wavelength selection and automatic calibration for precision, reproducibility, and ease-of-use. May be available as part of the Dionex DX-500 system and as a stand-alone unit.

Specification

Condition: Refurbished, Certified Pre-owned
Optical System: Dual-beam, fiber-optic beam splitter and concave holographic diffraction grating
Light Sources: Deuterium lamp (30 W) for ultraviolet spectrum analysis; tungsten lamp (10 W) for visible spectrum analysis
Wavelength Range: 190 to 800 nm variable; continuous in 1 nm steps
Wavelength Accuracy: ± 1 nm
Bandwidth: 8 nm
Absorbance Range: Discrete settings of 0.001, 0.002, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, and 2.0 AU
Autozero Capability: 2 AU
Autozero Accuracy: ± 100 uAU
Noise: < 10 uAU peak-to-peak at 254 nm, 2-second rise time, flowing deionized water
Drift:
< 100 uAU/hour (after warm-up)
< 100 uAU/oC (after warm-up)
Filter Rise Time: Discrete settings of 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, or 10.0 seconds
Analog Output Range: Discrete settings of 0.001, 0.002, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, and 2.0 AUFS
Cell Body: PEEK
Volume and Optical Path Length: Standard bore cell, used with 4 mm (0.016 in) columns: 9 mL volume, 10 mm (0.002 in) optical path length
Maximum Operating Pressure:
1.38 mPa (200 psi) with a heat exchanger;
3.45 mPa (500 psi) without a heat exchanger
Chemical Compatibility: The use of a base stronger than 0.1 M is not recommended, as it will etch the silica windows.

Features

Refurbished to meet manufacturer's specification
In excellent condition
Thoroughly cleaned
Money back guarantee
Certified with warranty

Related Products

Acquity UPLC Service, Waters
AD25 Absorbance Detector, Dionex
Agilent 1100 3D HPLC System, Agilent Technologies
Advertisement