Analysis Biomolecular Interactions of FcγIIIa/FcRn by BLI (CAT#: STEM-MB-0105-CJ)

Introduction

In immunology, a Fc receptor is a protein found on the surface of certain cells – including, among others, B lymphocytes, follicular dendritic cells, natural killer cells, macrophages, neutrophils, eosinophils, basophils, human platelets, and mast cells – that contribute to the protective functions of the immune system. All of the Fcγ receptors (FcγR) belong to the immunoglobulin superfamily and are the most important Fc receptors for inducing phagocytosis of opsonized (marked) microbes. This family includes several members, FcγRI (CD64), FcγRIIA (CD32), FcγRIIB (CD32), FcγRIIIA (CD16a), FcγRIIIB (CD16b), which differ in their antibody affinities due to their different molecular structure. For instance, FcγRI binds to IgG more strongly than FcγRII or FcγRIII does. FcγRI also has an extracellular portion composed of three immunoglobulin (Ig)-like domains, one more domain than FcγRII or FcγRIII has. This property allows FcγRI to bind a sole IgG molecule (or monomer), but all Fcγ receptors must bind multiple IgG molecules within an immune complex to be activated.




Principle

Bio-Layer Interferometry (BLI) is an optical technique for measuring macromolecular interactions by analyzing interference patterns of white light reflected from the surface of a biosensor tip. BLI experiments are used to determine the kinetics and affinity of molecular interactions. In a BLI experiment, one molecule is immobilized to a Dip and Read Biosensor and binding to a second molecule is measured. A change in the number of molecules bound to the end of the biosensor tip causes a shift in the interference pattern that is measured in real-time.

Applications

Immunology/Inflammation; Pharmacology

Procedure

1. Detect Buffers and prepare samples. BLI experiments are set up with one molecule immobilised on the surface of the biosensor (load sample) and a second molecule in solution (the analytical sample).
2. Fix the load sample on the biocompatible biosensor while the analytical sample is in solution.
3. The biosensor tip is immersed in the solution so that the target molecule begins to bind to the analysis sample.
4. Set up and run the BLI experiment. Molecules bound to or dissociated from the biosensor can generate response curves on the BLI system; unbound molecules, changes in the refractive index of the surrounding medium or changes in flow rate do not affect the interferogram pattern.
5. Collect and analyse data on the BLI's system.

Materials

• Equipment: Fortebio Bio-Layer Interferometry (BLI)
• Sample Type: DNA, RNA, Protein, Antibodies, Peptides, Small Molecules
• Optionals: CHO Cells